HBO 12000 W/CHL

Areas of application
  • Microlithography
Safety advice
Because of their high luminance, UV radiation and high internal pressure (when hot) HBO lamps may only be operated in enclosed lamp casings specially constructed for the purpose. Mercury is released if the lamp breaks. Special safety precautions must be taken. More information is available on request or can be found in the leaflet included with the lamp or in the operating instructions.
NON HOUSEHOLD ILLUMINATION Pictogram Industry

Technical Data

General Product Information

Global order reference

HBO 12000 W/CHL

Electrical Data

Nominal wattage

12000 W

Nominal voltage

113 V

Nominal current

106 A

Type of current

DC

Photometric Data

Light center length (LCL)

200.0 mm

Distance from end of base to tip of anode or cathode (cold)

Physical Attributes & Dimensions

Electrode gap (cold)

11.0 mm

Base (anode)

SFaX46-14/60

With cable connection (M 10)

Base (cathode)

SFa37-16/60

Diameter

124.0 mm

Length

500.0 mm

Length with base excl. base pins/connection

450.00 mm

Connector: presence

Yes

Product weight

3144.00 g

Operating Conditions

Burning position

Other

Anode on top

Cooling

Forced

Maximum permissible base temperature: 200 °C

Lifetime Data

Nominal lifetime

1500 hr

Environmental & Regulatory Information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Primary article identifier

4008321651129 | 4052899422322 | 4062172416436 | 4062172416429

Declaration no. in SCIP database

405e8bdf-87f2-46eb-9530-aa1f4ca56abe|6965d23e-72f4-4e35-a198-04b8540e751e

Candidate list substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe use instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4008321651129 VS

SHIPPING BOX

1 400mm x 400mm x 900mm 7177.00g 144.00dm³

Downloads

Technický list výrobku