HBO 350 W
Safety advice
Because of their high luminance, UV radiation and high internal pressure (when hot) HBO lamps may only be operated in enclosed lamp casings specially constructed for the purpose. Mercury is released if the lamp breaks. Special safety precautions must be taken. More information is available on request or can be found in the leaflet included with the lamp or in the operating instructions.
Technical Data
Electrical data
Nominal voltage
67.5 V
Nominal current
53 A
Type of current
DC
Rated wattage
350.00 W
Nominal wattage
350.00 W
Dimensions & weight
Diameter
20.0 mm
Length
128.0 mm
Electrode gap cold
3.0 mm
Additional product data
Base anode (standard designation)
SFcY10-4
Base cathode (standard designation)
SFcY10-4
Product remark
Lamp suitable for pulse operation between 250 500 W. Maximum permissible power is 350 W for constant power operation. Duty cycle 12 h ON/30 min OFF
Capabilities
Burning position
Other
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
05-03-2024
Primary Article Identifier
4050300351599
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
69139dd2-ff81-43c7-bcfa-b84bcd0b9cc1
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4050300351599 |
VS
| 1 | 215mm x 70mm x 95mm | 174.67g | 1.43dm³ |
Country specific information
EAN |
METEL code |
---|---|
4050300351599 | OSRHBO350 |
4050300953359 | OSRHBO350 |