XBO 100 W OFR

Product features and benefits
  • High luminance / radiance with intense point source
  • Broad, continuous spectral distribution
  • High color rendering > 95
  • High arc stability
  • DC operation
Areas of application
  • Endoscopy
  • Microscopy
  • Surgical Headlamps
  • Fiber Illumination
  • Solar Simulation
  • Imaging & Scanning
Safety advice
Because of their high luminance, UV radiation and high internal pressure in both the hot and cold state, XBO lamps must only be operated in appropriate enclosed casings. Always use the protective jackets supplied when handling these lamps. They may only be used as open lamps if appropriate safety measures are taken. More information is available on request or can be found in the leaflet included with the lamp or the operating instructions.
NON HOUSEHOLD ILLUMINATION Medical pictogram

Technical Data

General Product Information

Product number (Americas)

69233

Product name (Americas)

XBO 100W OFR 14V 10/CS 1/SKU

Family brand

XBO

Lamp type

DOUBLE ENDED

Product remark

OFR = Ozone-free version

Global order reference

XBO 100 W OFR

Electrical Data

Nominal wattage

100 W

Lamp voltage

12.8…14.4 V

Initial voltage range

Lamp current

7.0…7.4 A

Type of current

DC

Photometric Data

Nominal luminous flux

1900 lm

Luminous intensity

270 cd

Typical initial photometric value

Color temperature

6000 K

Color rendering index Ra

98

Light center length (LCL)

44.5 mm

Distance from end of base to tip of anode (cold)

Physical Attributes & Dimensions

Electrode gap (cold)

0.9 mm

Base (anode)

SFa9-2

Base (cathode)

SFa7.5-2

Diameter (in)

39.331 in

Diameter

11.0 mm

Length

90.0 mm

Product weight

12.00 g

Operating Conditions

Burning position

s100

If vertical, then anode on top; up to 10° below horizontal, cathode on top

Cooling

Convection

Lifetime Data

Average life - vertical

500 hr

Average life - horizontal

500 hr

Environmental & Regulatory Information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Primary article identifier

4008321386328

Declaration no. in SCIP database

ac5c5363-ba12-4018-9516-c8896069720e

Candidate list substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe use instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4008321386328 FS

FOLDING BOX

1 224mm x 95mm x 60mm 98.00g 1.28dm³
4008321386335 VS

SHIPPING BOX

10 306mm x 235mm x 200mm 1365.00g 14.38dm³

Country specific information

EAN

METEL code

SEG number

4008321386328 OSRXBO100OFR 8333500